Sliding Gate Operator Automatic reverse when obstacle ET-S500 ET-S800 Manual for installation and operation 1

Contents 1.1ET-S500\ET-S800 products and accessories .................................................. 4 1.2 Dimension ...................................................................................................... 5 1.3 Gate variations ............................................................................................... 5 2.1 General notes ................................................................................................. 6 2.2 Checks ............................................................................................................ 6 2.3 Gate and foundation layout ............................................................................ 8 2.4 Cabling layout ................................................................................................ 9 3.1 Installing the motor unit ............................................................................... 10 3.2 Mounting the toothed rack ........................................................................... 12 3.2.1 General ................................................................................................ 12 3.2.2 Determining the installation height .................................................... 12 3.2.3 Determining the length and installation position of the toothed rack ...................................................................................................................... 13 3.2.4 Adjust the length of the toothed rack............................................... 14 3.2.5 Mounting the toothed rack ............................................................... 15 3.2.6 Adjust the motor unit ....................................................................... 16 3.3 Adjusting the height of the motor unit ......................................................... 17 3.4 Mounting the reference point magnet .......................................................... 17 3.5 Release ......................................................................................................... 19 3.6 Locking .......……………………………………………………………….19 3.7 Restore the limit setting after power restoration ....................................... 20 2

4.1 Connection of Mains cable .......................................................................... 21 4.2 Connection of control elements ................................................................... 22 4.2.1Wireless closing edge safety device connection .................................. 22 4.2.2 Infrared beam connection ................................................................... 23 4.2.3 Opening edge and closing edge safety device connection ................. 23 4.2.4 "O/S/C" button connection ................................................................. 24 4.2.5 Caution light connection ..................................................................... 24 4.2.6 Battery backup connection ................................................................. 24 4.2.7 Pedestrian mode .................................................................................. 24 4.3 Setting the function ...................................................................................... 25 4.4 Hand transmitter coding............................................................................... 26 5.1 Technical feature of sliding gate operator.................................................... 27 6.1 FAQ .............................................................................................................. 28 3

1.1ET-S500\ET-S800 products and accessories Standard products and accessories 1-1-3 8. Hand transmitter 9. Wall mounting bracket 10. Set screw of bracket 11. Plastic expansion In addition to the components in the standard package,the following is required for the installation: — Toothed rack 1-1-1 1. ET-S500\ET-S800 motor unit Toothed rack 2. Keys 3. M8 wall plugs 1-1-4 1-1-2 The toothed rack and accessories includes: 4. Block of magnet housing 5. Reference point magnet 12. Toothed rack 6. Cover of magnet housing 13. Set screw for toothed rack 7. Magnet housing 14. Washer 15. Fixing nuts for toothed rack The quantities of the individual components are dependent on the gate length. 4

1.2 Dimension 1.3 Gate variations The standard supply package is suitable for the following types of gates. Gate system on rails 1-3-1 1-2-1 Cantilevered gate system 1-2-2 1-3-2 5

2.1 General notes 2.2 Checks The picture in these instruction are not Attention! true-to-scale. In order to guarantee correct All the dimensions are shown in mounting,carry out the following millimeters(mm)! checks before installation. The motor can be mounted on the right or left hand side of the gate depending 在工作开始前进行以下的检查 on the direction of opening. These instructions show the motor being Supply contents : installed on the right hand side. z Check the package to ensure that all For correct mounting you will need the the parts are included. following tools: z Check that you have all the additional components that are necessary for your particular installation requirements. Foundations z Check the proposed installation location for the operator system: — The motor unit and the toothed rack must be installed on the Φ12 inside of the gate with the gate closed. — The motor unit should not be installed within the clear width! — For cantilevered gates, the motor unit must be mounted at the mid point between the carrier roller assemblies. — The foundations must be suitable for heavy duty wall plugs. z Check whether the existing foundations are suitable. 2-1-1 * Minimum shaft length is 160mm. z Check the supply cable. Pay particular attention to the cable exit point where the motor unit is to be installed. 6

Gate system z Ensure that your gate system has an appropriate electricity supply connection and a facility for disconnecting the mains. The minimum cross-sectional area of the earth cable is 3×1.5mm2 z Ensure that all cables are suitable for outdoor use(cold resistant and UV resistant). z Check that the gate to be operated fulfils the following conditions: — The travel path of the gate must be horizontal. — When closed, the gate should exceed at least 400mm further than the height on the same installation side. — The gate must have a mechanical gate stop for both direction. — The closing edges must be fitted with a flexible gate seal. — The gate itself must be straight, so that the distance between motor unit and the gate never changes. 7

2.3 Gate and foundation layout 2-3-1 A Empty conduit for control cable B Empty conduit for electricity supply cable q Gate width r Clear width s Opening direction t Below depth of frost penetration x Gate thickness+ distance from structure 8

2.4 Cabling layout Advice: This is just an example of a cabling layout,the layout can vary according to the type of gate and the associated equipment. 2-4-1 1 Signal transmission system 4 Closing edge safety device 2 Infrared beam SKS 3 Caution light 5 Mains isolater switch(mains disconnection facility) Reference: For the installation and cabling of the gate sensors, control elements and safety equipment ,the relevant installation instructions must be observed. 9

3.1 Installing the motor unit Attention! To install the motor unit correctly, it must be mounted at the mid Attention! point between the carrier roller To install the motor unit assemblies if the gates are correctly,the following points cantilevered. must be assured: —The spur gear must accurately mesh with the toothed rack. — The wall plugs for the floor console must be at least 80mm from the edge of the foundation. 3-1-3 A Wall B Gate 3-1-1 C Mounting surface for the toothed rack D Output shaft of the motor unit E Front edge of the toothed rack F Floor console G Clear width H Cable entry for power supply/control cable I Foundation 3-1-2 Open the motor unit cover. 10

Reference: When determining the mounting surface for the toothed rack, the information given in section 3.2.2 must be observed. Notes: Caution! When using an existing toothed Danger of electric shock: rack, the correct dimension is Before commencing cabling 27mm from the first screw to the works it is very important to front edge of the toothed rack. disconnect the operator system from the electricity supply. Ensure that the electricity z Before installing the motor unit, supply remains disconnected for check whether the possible height the duration of the cabling works. adjustment of the motor unit is sufficient for the situation on site,or if the motor unit needs to be raised on a backplate. z Align the floor console ,with the motor unit parallel to the gate. Reference: The height adjustment of the motor unit is described in section 3-1-4 3.3. z Push in the wall plugs z Feed the control cable and the z Drill the holes for the wall plugs as power supply cable through the shown in the drilling diagram. floor console. z Adjust the motor unit z Screw the floor console into place 11

3.2 Mounting the toothed 3.2.2 Determining the rack installation height 3.2.1 General Attention! To ensure trouble-free movement of the Attention! gate,the following points must be assured: To install the rack —The screws A should not obstruct the correctly,the following operation of the gate.(e.g. by extending into must be ensured: the path of the gate rollers(B).) — The motor unit has been —The spur gear(C)should not rest against mounted. the gate. — The motor unit is released. —The spur gear C is should not be too low to avoid mesh apart with the rack. There must be 1-2mm clearance at the point that meshed Reference: — For gates with an existing toothed rack,please skip to Section 3.3. — Section3.5 describes how to release the motor unit. Toothed rack are available in several standard lengths and some fixing rack accessories. 3-2-1 The toothed rack is made up of several z Determine the installation height of toothed rack segments. the toothed rack on the gate Minimum length of toothed rack z Adjust the height of the spur gear Minimum length of toothed rack is equal accordingly. to the movement stroke of the gate between the gate OPEN and CLOSED Reference: positions+180mm Maximum length of toothed rack Section 3.3 describes the height adjustment for the motor unit. Maximum length of toothed rack is equal to the width of gate. Notes: The toothed rack can be adapted to fit the gate by means of backplate(D). 12

3.2.3 Determining the length and installation position of the toothed rack Maximum length of toothed rack If a toothed rack is to be installed across the entire width of the gate ,then the installation position does not have to be determined. The length and installation position of the toothed rack correspond to the gate width. 3-2-3 z Move the gate to the OPEN position. Minimum length of toothed rack z Make a mark on the gate: The minimum length of toothed rack z 90mm from the centre of the spur must be determined at the gate. gear in the direction of closing. Attention! To ensure trouble-free operation, the toothed rack must at least extend across the area(E) between the markings. 3-2-2 z Move the gate to the CLOSED position. z Make a mark on the gate: 90mm from the centre of the spur gear in the direction of opening. 3-2-4 13

3.2.4 Adjust the length of 3-2-5 the toothed rack When the standard rack length is Attention! shorter than the required length. To avoid damaging the toothed rack segments , there should be no toothed rack segments in the rack housing at the point where the cut is to be made. z Measure the required length of the toothed rack at the gate. Change the standard length to required length of the toothed rack: The toothed rack need not to be 3-2-6 adjusted. z Place the required number of the toothed rack end to end. When the standard rack length is z Cut off any excess length from the longer than the required length: last toothed rack using a metal saw. Cut off the excess length of the toothed rack using a metal saw. 14

3.2.5 Mounting the toothed 3-2-8 rack z Hold the toothed rack in place according to the fixing rack nuts Attention! welded on the gate on the spur To ensure the gate can move gear side. smoothly, the countersunk screw z Place the toothed rack onto the must be tightened and adjusted spur gear so that the toothed rack accordingly.When welding the engages the spur gear. fixing rack nuts, make sure to z Adjust the toothed rack weld the smaller end to the gate horizontally. barrier, and the bigger end face to z Using a spanner to hold the the toothed rack. All the surface toothed rack in position of the of bigger ends must flush with fixing rack nuts. each other. Fixing nuts need to be welded on different position of the gate before installing the toothed rack. 3-2-7 3-2-9 Reference: z According to the above-mentioned The reference point magnet process, place other racks with the must be installed before the rack is bolts to the fixing rack nuts. mounted. Section 3.4 describes how to install the reference point Attention! magnet. To ensure correct operation, the toothed rack must always be pushed onto the spur gear as the gate is moved. 15

3.2.6 Adjust the motor unit Attention! To ensure the gate runs smoothly, it is important that a vertical gap of 1 to 2mm is maintained between the toothed rack and the spur gear. 3-2-10 z Push the gate one cycle in the direction of closing by hand, and adjust the clearance between the rack and spur gear. z Tighten all the nuts after adjusting the height. 3-2-11 The height of the motor unit must be re-adjusted now. z Lower the spur gear by 1 to 2mm Reference: Section 3.3 describes how to adjust the height of the motor unit. Check: To check that the spur gear engages the toothed rack along its entire length,the gate must be pushed once to the OPEN position and back to the CLOSED position. 16

3.3 Adjusting the height of 3.4 Mounting the reference the motor unit point magnet Caution! To avoid injury ,the gate must have a mechanical end stop in both directions; otherwise it could spring out of line. Attention! 3-3-1 To ensure correct operation, any existing magnets must be removed.(e.g.in the case of retrofit measures with an existing toothed rack). The operator system determines the gate positions and the extent of travel electronically. So it requires a reference point on the gate or on the toothed rack. Using a special reference point magnet as the reference point. 3-3-2 z According to the Fig.3-1-4,tighten the bottom screw A after fixing the wall plug. z Adjust the Nut(B) in the middle of the wall plug until the motor is in suitable position. z Tighten screw(C) at the top after fixing the flat washer and spring washer. 3-4-1 z Drive the door to the CLOSED position 17

z Determine the position for the reference point magnet. Attention! To avoid faults occuring, the following dimensions must be 3-4-5 adhered to without fail: — The distance between the z Mount the reference point magnet reference point magnet(A) and the in the magnet housing. motor unit(B) must be 2 to 8mm. z Mount the cover onto the magnet —The distance between the centre of housing. the magnet(A) and the centre of the z Mount the magnet housing at the spur gear(C) must be 70mm. previously determined position on the toothed rack. z Check the position of the reference point magnet. z Check the distance between the reference point magnet and the motor unit. z Check the distance between the centre of the reference point magnet and the internal hall height of the motor unit. 3-4-2 The mounting of the reference point magnet is dependent on the type of toothed rack that is used. 3 3-4-4 18

3.6 Locking 3.5 Release 3-5-3 z Hold the triangle plastic part outside 3-5-1 the lock, turn anti-clockwise by z Place the release key into the 180·until it stops. Push the door keyhole at the bottom of the motor unit. front and back by hand to ensure the gear is engaged. 3-5-2 3-5-4 z Hold the triangle plastic part z Pull the key out of the keyhole at outside the lock, turn clockwise by the bottom of the motor unit. 180·until it stops. The transmission and drive shaft are z Move the door shortly by hand in now mechanically engaged. The gate the OPEN and CLOSE direction. can be driven via the motor. The The transmission is now mechanically electric circuit in the controls are in disengaged from the drive shaft. The operation. gate can only be moved manually. The electric circuit in the controls is interrupted and the controls are out of operation. 19

Attention! z Do not rotate the key ! When re-engage after releasing, limit movement may happen. please use the transmitter, wall switch or built-in control panel to open or close the door and let reference point magnet pass the drive unit one time. then the travel limit setting will be recovered automatically.. 3.7 Restore the limit setting after power restoration When the power restoration, please use the transmitter, wall switch or built-in control panel to open or close the door and let reference point magnet pass the drive unit one time. then the travel limit setting will be recovered automatically. If not, the door opening/closing position will be error. 20

4.1 Connection of Mains 4-1-2 cable z Put the mains cable with protector jacket through the hole at the bottom of the motor unit. Attention: z Loosen the screws on the terminal block, then connect the two peeled The sliding gate operator end(L N) to the terminals on the should use: terminal block, tightened the screws. ---AC220V (or Connect the ground wire to the earth AC240V/AC110V) power terminal of the motor, make sure it is supply. tight. ---To be installed by z Fix the mains cable together with professional technicians, and to the motor wire using cable ties. use the cables fit safety standard 3 × 0.75mm ². z Close the cover of the junction box, and then tighten the screws. 4-1-1 4-1-3 z Open the cover of the motor unit, loosen the two fixing screws on the z Fix the cable plugged into the junction box at the wall side of the motor to the hole like the drawing. motor,and open the cover. z 21

4.2 Connection of control elements Wireless protector receiver Infrared beam Closing edge safety device(closing direction) Opening edge safety device(opening direction) O/S/C button Caution light Battery backup 4-2-1 4.2.1Wireless closing edge safety device connection The connection is suitable for the wireless safety device with DC24V and NC type. Section 4-2-1 describes how to connect the wireless safety device . Attention! Please shorten the two terminals “COM” and “SAFE” by wire conductor if this function is not required, or the motor will not be able to close the gate. 22

4.2.2 Infrared beam connection 4.2.3 Opening edge and closing Attention! edge safety device connection To correctly operation, we z This is suitable for pressing to strongly advise to use infrared short-connected safety device. beam with three-wire,on-off controlled, DC24V, the control z Connect an 8.2 kΩ resistor to the far end contact points is NC style. of the closing edge safety device. z Section 4-2-1 describes the connection of “Infrared beam” z Section 4-2-1 describes the connection of “closing edge safety z Activate the infrared beam(H1 or device-closing direction” and H2) by the setting interface “closing edge safety device-opening “P4”.Press „SET‟ button and hold direction” on until the LED displays figure „P4‟,then press ”SET” once to confirm, the LED will displays”H1or H2”,then the Attention: function is available. When the safety device is not used, an 8.2 kΩ resistor is required to be z When the self-checking function of installed at the relevant terminals. infrared beam(H2) is activated, the When the resistance of the safety motor will not work if the protector device is far below 8.2 kΩ,(corresponds is failure, the LED will display “r”. to the shor-connecting of the safety device),or the resistance is much higher z If the connection is OK, the lamp than 8.2 kΩ,(equals to the open circuit “PE” will normally on during of safety device), the relevant CEP light closing cycle,will off when it is will normally on, and the motor will not obstructed. work. Attention: If the infrared beam is not used, please disable the function, as the same setting “P4 → HO”, or the gate can not be closed by the motor.(Please according to section 4.3) 23

4.2.4 "O/S/C" button 4.2.6 Battery backup connection connection Section 4-2-1 describes the connection of “O/S/C button”. z The section 4-2-1 described the connection of the battery backup. Attention: z Use the battery 24V, ≥ 3.6AH,the Please choose the one-touch wire cross-sectional area ≥ switch. 0.75mm2 × 2. Use the 2 × 0.4mm2 Please note“+, -” polarity, and fix by plastic-covered cable to connect. the professional electrician. 4.2.7 Pedestrian mode 4.2.5 Caution light z Set according to section4.3, when connection the LED displays”0”,this function is invalid. When the LED displays “1”, the z Section 4-2-1 described the door will be opened to the 30cm position. connection of caution light. When it displays”2”,the door will be opened to the 60cm position, and so z The caution light will go on during forth. When the LED displays ”9”,the opening and closing,will go out when door will be approximately opened to stopped. the 270cm position. z The output voltage is DC24V, and the maximum current is :800mA. Please choose the caution light DC24V , ≤ 20W, and use the 2 × 0.5mm2 wire to connect 24

4.3 Setting the function 25

4.4 Hand transmitter coding Press and hold „CODE‟ button over than 8 seconds, the LED dot lights up. And then press “O/S/C” button on the transmitter, the LED goes out. Press “O/S/C” button once again ,the LED fast flashed 8 times. The transmitter coding finished. Attention: Press and hold “CODE”button until the LED dot lights up,all the transmitters codes held in the memory will be erased. This operator can learn at least 20 transmitters. Auto reverse: The gate will stop when obstacle during the opening. The gate will reverse when obstacle during the closing. 26

5.1 Technical feature of sliding gate operator Model 500KG 800KG Model 500KG 800KG Input Caution light AC220~240V AC220~240V one group one group voltage connector Opening Working edge safety DC24V DC24V one group one group voltage device connector Closing edge Rated 150W 180W safety device one group one group Power connector Wireless Rated pull security 210N 260N one group one group force switch connector Infrared Rated 7NM 10NM beam one group one group torque connector Max travel O/S/C 10M/MIN 10M/MIN one group one group speed connector Max Opening 10M 10M Auto reverse YES YES width Automatic 120S 120S Soft start YES YES closing time Transmitter 433.92Hz 433.92 Hz Soft stop YES YES frequency 27

6.1 FAQ Error Possible causes Advised solution No reaction on the operator. 1 Power failure. ※1 Check plug and power 2 Connecting wire loosen supply. between transformer ※2 Loosen the four screws of and main board. the control box on the cover, re-fit the referent plug. Motor does not work, there is The clutch is in the Engage the clutch. “da da” sound inside the disengaging state. motor, as well as the LED displays“— —”. Motor does not work, there is Opening and closing limit Reset the travel limit according to no sound inside the motor, and has not been set. the instruction. the LED displays“— —”. Only opening allowed,and the The infrared beam function Enter the setting interface (P4→ is activated, but has not been LED shows “— —”or ”r”. connected. HO), and close the function.(we suggest to use the infrared beam) Only opening allowed, and the Has not connected the Installed the wireless protector or CDP light is off. wireless protector, and the shorten the two terminals “COM” relevant terminal has not and “SAFE”.And now the CDP been short circuited,or short light will be on. wires is loosen. Can not opened or closed,the 1 Did not connect the 8.2 1 As required, connect an 8.2 CEP or the OEP light is on . kΩ reference resistor kΩ reference resistor to the when fixing the safety far end of the safety device. device. 2 Re-connect the 8.2 kΩ 2 The 8.2 kΩ reference reference resistor. resistor loosen when the 3 Get rid of any open or shorted safety device not faults of the safety device. connected. 3 Faulty wiring in safety device. After setting the travel limit, in Has not installed the Re-install the reference point the process of auto-learn ,the reference point magnet or magnet as required and ensure motor stopped automatically, the installation position is that when the motor passed as well as the LED shows “E”. out of place. through the reference point magnet, the signal light will be on. 28

The motor exceed the travel Reference point magnet Re-install the reference point limit and not stop. come off or dislocated. magnet as required and re-set the travel limit. Opening and closing turn The setting of the right hand Press the “SET” button until the upside down. or left hand installation is LED shows “P6”. And then wrong. change the right hand and left hand installation. Right hand installation is “Lt”, right hand installation is “rt” . The gate can not be fully Some obstacle in the gate. 1 Remove the obstacle and try closed but reversed 20cm. again. 2 Re-set the travel limit. 3 Increase the auto-reverse force. Automatically stop during Some obstacle in the gate 1 Remove the obstacle and try opening. and the motor auto stop. again. 2 Re-set the travel limit. 3 Increase the auto-reverse force. The motor stops automatically ※1 Re-plug Hall sensor wires. 1、 Hall sensor wires after running few centimeters ※2 Check or replace Hall sensor in both opening and closing loosen. wires. cycle, the LED shows H . 2、 Hall sensor damaged. ※3 Replace control circuit board . 3、 Failure on circuit board. The hand transmitter is out of 1 Replace battery. 1、 Battery has run out. use or has short remote control 2 Check and stretch aerial. distance. 3 Eliminate source of 2、 Aerial goes off or has disturbance. not been stretched properly. 3、 Any radio interference nearby. Hand transmitter can‟t be 1 Full memory in the 1 Erase all memories and learnt. transmitter(The motor re-coding Press “CODE” can be learnt by 20 button until the LED shows transmitters). “dL” . 2 The transmitter which 2 Use the transmitter we you used is not the one supplied. supplied with the motor. 29

When re-engage after After re-engaging ,the please use the transmitter, releasing, limit movement beginning of travel is not wall switch or built-in control happened. synchronous. panel to open or close the door and let reference point magnet pass the drive unit one time. then the travel limit setting will be recovered automatically The power restoration after when power restoration, Plesae make sure the clutch power failure , the limit the motor can not is engaged . then please use movement happened. distinguish the current the transmitter, wall switch or position. built-in control panel to open or close the door and let reference point magnet pass the drive unit one time. then the travel limit setting will be recovered automatically Note: The Asterisk(※)solution should be finished by professional technician. 30